TX® (C) 331 150/250V 14P0.75

Description

Description

Standards

  • Product
    448-010-3-10; IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TX® (C) 331  150/250 V fire resistant overall screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables provide a medium protection aganist external electromagnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

  1. Conductor:
    Bare copper
    Stranded class 2
     
  2. Insulation: 
    Mica tape + XLPE (cross-linked polyethylene)
    Optional: Special fire resistant HF 90 (halogen-free compound)
    with INFITTM technology
  3. Collective screen:
    Alu/polyester tape with a tinned copper drain wire
     
  4. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: orange
     

Marking

I NEXANS I - TX (C) 331  150/250 V  "n" x 2 or 3" x s" mm²  90 °C  IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 ww/yy - *CE* + metric marking

 

Core identification

Core 1: white
Core 2: blue
Core 3: red
Double identification:  core and pair.

 

 

Characteristics

Characteristics

구조적 특성

구조적 특성

Halogen free
IEC 60754-1
도체 재료
베어 구리 와이어
Conductor flexibility
트위스팅 레벨 2
절연
특수 할로겐 프리 방화
스크린
Collective screen : Polyester tape/Foil Alu
Drain wire
주석 도금 구리
피복
폴리올레핀
Sheath colour
주황색

치수

치수

Number of pairs
14
Number of triples
-
도체 단면적
0.75 mm²
Minimum outer diameter
19.5 mm
Nominal outer diameter
- mm
Maximum outer diameter
22.5 mm
무게(근사치)
510 kg/km

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
150 / 250 (300) V
20° C에서 최대 도체 DC저항
52 Ohm/km

사용 특성

사용 특성

Fire retardant
EN IEC 60332-3-22 (cat A)
Fire resistant
IEC 60331-21, IEC 60331-1 or 2
연기밀도
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
操作温度范围
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close